Connecting Devices to the CVG 14
Figure 10: RS232/485 adapter
Note: If you connect an ADAM module to the unit, you cannot connect any RS232 PTZ controllers, a touch-
screen controller, or an IA relay board to the unit. For additional information, see Connecting a PTZ
Controller, page 9; Connecting a CCTV Monitor, page 18; Connecting Sensors and Activators Using an IA
Relay Board, page 16.
5. Connect the ADAM-4051 module to the power source as follows (see figure 11, page 15):
Connect the positive (+) wire of the power supply cable to the (R) +Vs connector on the module
Connect the negative (-) wire of the power supply cable to the (B) GND connector on the module
Note: Each of the power connectors on the module will then have two wires connected to it – one connecting
it to the power supply, and one connecting it to the power connectors of the ADAM-4520 converter.
Plug into RS232/485